Product Description
DA 2450 Extractor Unit With LED Lighting
Construction type
- Integrated extractor
Design
- Colour No colour
- RAL colours available as customisation on request
- Customisation possible on request
Operating modes
- Type of air guide Convertible
- Active charcoal filter (order separately) DKF15-1
User convenience
- Electronic controls
- Rotary knob
- Power levels (number without Booster level) 2
- Booster level
Cleaning convenience
- Easy-to-clean canopy interior – CleanCover
- Filter system
- Number of dishwasher safe stainless steel grease filters 1
Lighting
- LED
- Light intensity in Lx 330
- Colour temperature in K 3000
Fan
- Dual-action fan
- AC motor
Air throughput with max. duct diameter in extraction mode (not for external version)
- Air throughput in Level 1 (m³/h) 230
- Air throughput in Level 2 (m³/h) 350
- Air throughput in Booster level (m³/h) 590
- Sound power in Level 1 (dB(A) re 1 pW) 47
- Sound power in Level 2 (dB(A) re 1 pW) 54
- Sound power in Booster level (dB(A) re 1 pW) 66
- Sound pressure in Level 1 (dB(A) re 20 µPa) 32
- Sound pressure in Level 2 (dB(A) re 20 µPa) 40
- Sound pressure in Booster level (dB(A) re 20 µPa) 52
Air throughput in recirculation mode
- Air throughput in Level 1 (m³/h) 185
- Air throughput in Level 2 (m³/h) 305
- Air throughput in Booster level (m³/h) 525
- Sound power in Level 1 (dB(A) re 1 pW) 52
- Sound power in Level 2 (dB(A) re 1 pW) 61
- Sound power in Booster level (dB(A) re 1 pW) 71
- Sound pressure in Level 1 (dB(A) re 20 µPa) 38
- Sound pressure in Level 2 (dB(A) re 20 µPa) 47
- Sound power in Booster level (dB(A) re 1 pW) 57
Technical data
- Canopy width in mm 532
- Canopy height in mm 50
- Canopy depth in mm 372
- Net weight in kg 10.2
- Length of supply lead in m 1.5
- Standard plug fitted
- Total rated load in kW 0.23
- Voltage in V 230
- Fuse rating in A 10
- Number of phases 1
Installation notes
- Extraction ducting connection at top
- Extraction connection at top and rear
- Diameter of extraction ducting connection in mm 150
Standard accessories
- Non-return flap
- Adapter to reduce ducting diameter from 150 mm to 125 mm Ø